Problem description
One more thing, what protocol and speed is used between the servo controller and the destacker 1/2 servo motors?
I’m asking because we moved the first two control boxes to different place. I need to order longer cables for the destacker 1/2 servo motors. For RS-232 the max length is 20m. For RS-422 the max length is 1200m. We need about 30m long cables.
Based on the electric drawing I think it’s RS-422. I already contacted a local company here in Slovakia and provided them with all the details. I hope they confirm my assumption and the will make the cables for us.
Solution
The servo motor is made by Delta, a Chinese brand. It may be difficult to find foreign connectors. Extending the motor cable is not a problem, but if the encoder cable is too long, it may need to be replaced. A long encoder cable can lead to signal attenuation and interference issues. A 30m encoder cable needs to be thickened and shielded with twisted pair wires and magnetic rings. However, this method cannot guarantee 100% avoidance of attenuation and interference problems. It is recommended to consult Delta to request a cable for the encoder that is specifically designed to avoid these issues. The manufacturer’s cable should be able to avoid these problems.
Suit for EPS machine
Leave a Message