The 1100 type EPS batch pre-expander machine uses fixed opening degrees for compressed air proportional valves and controls pressure chamber pressure through the top exhaust valve. The 1200 type EPS batch pre-expander machine requires stable steam temperature and pressure. If the compressed air pressure is low, the pressure of the compressed air filter regulator for the steam proportional valve should be adjusted. The steam temperature and pressure are controlled by the chamber thermometer gauge and pressure gauge, respectively.

Description

Working principle of 1100 type EPS batch pre-expander machine

The 1100 pre-expander machine achieves different expanding densities by setting the pressure of the steam chamber, and the upper and lower pressure settings of the steam chabmer.

In the process of heating, the steam valve is always open, and after reaching the pressure, the pressure chamber pressure is controlled by opening the top exhaust valve.

Temperature: not controlled, the temperature is only for display, not for control .

Compressed air proportional valve is the opening degree is fixed.

compressed air proportional valve is mainly to use for expand the heavy density.

Working principle of 1200 type EPS batch pre-expander machine

What’s the relation between steam proportional valve and compressed air proportional valve

The EPS batch pre-expander machine needs a stable steam temperature and pressure during expanding.

If the compressed air pressure is low, it will not open all valves properly. If a steam proportional valve fails to open, adjust the pressure of the compressed air filter regulator for the steam proportional valve to ensure that compressed air can open and close the steam proportional valve properly.

Proportional Valve 0 = Closed

Proportional valve 100 = fully open

The compressed air proportional valve can generally be used without it. The steam temperature of the steam chamber is controlled by the chamber thermometer gauge, and when it reaches the set temperature, the compressed air proportional valve is opened to cool the steam chamber.

The steam pressure of the chamberl is controlled by the pressure gauge, when it reaches the set pressure, the steam proportional valve is closed, when it does not reach the set pressure, the proportional valve is opened to continual supply the steam into the chamber.

Photo