The five most common alarms of ESP shape molding machines

The five most common alarms of ESP shape molding machines

This page discusses the five most common alarms of ESP shape molding machines. When an alarm occurs, the touch screen prompts for troubleshooting, and you can access the input page for real-time info.

Suit for EPS machine

Description

We will explain the five most common alarms on the input screen of the EPS shape molding machine.

When the EPS shape molding machine has an alarm, the touch screen will automatically pop up an alarm prompt to help do the troubleshooting, at the same time you can also enter the input page to view real-time information:

  • Hydraulic motor normal: X20
  • Vacuum motor overload: X21
  • Filling motor overload: X22
  • Level sensor:
    • Hopper level 1: X37
    • Hopper level 2: X40
  • Safe gate alarm:
    • Front safe gate X24
    • Back safe gate X25
The five most common alarms of ESP shape molding machines