修改图片名称

Steam accumulator for EPS production line

Using a steam accumulator in the EPS production line can balance steam demand and production, allowing excess steam to be accumulated during low demand periods and providing additional steam during peak periods. This allows the boiler to run at a mean load, and the boiler capacity can be chosen according to the average load instead of the maximum load. The steam plant should be designed by calculating the steam accumulator volume and boiler operation pressure in proportion before making an investment.

Description

The EPS production process requires a steam pressure between 6 to 8 bar.

The amount of steam consumed during the EPS process ranges from 15 kg to 25 kg per cubic meter of manufactured EPS block.

The steam consumption per cubic meter of manufactured EPS decreases as the block volume of manufactured EPS increases. This steam amount is a value determined for each loop. To calculate the hourly steam consumption, this steam consumption value is multiplied by the number of loops in an hour.

Steam consumption in EPS production reaches a peak point in every loop and drops to zero after heating is complete. This means that steam consumption during the process follows a sinus curve with ups and downs, causing steam boiler load changes between a minimum and maximum load in every cycle. In this case, the steam boiler capacity should be selected according to the maximum steam load. However, the steam boiler cannot respond to the maximum steam demand of the process in seconds.

The best way to balance steam demand and production is by using a steam accumulator at the EPS plant. This allows excess steam to be accumulated in the steam accumulator when steam consumption in the process drops, and the steam accumulator can provide additional steam during peak periods. The steam accumulator allows the boiler to run at a mean load, so the boiler capacity can be chosen according to the average load instead of the maximum load.

Steam boiler operation pressure should be higher than the pressure required by the EPS process for the steam accumulator to be effective. The boiler operation pressure and steam accumulator volume should be chosen proportionally according to the steam consumption of EPS production in every cycle. For example, if the EPS process requires 6 bar of steam, the boiler operation pressure should be chosen as 10 bar or 12 bar. In this case, the steam boiler charges the steam accumulator up to 12 bar when steam consumption in the process drops, and the steam accumulator offers extra steam by using a pressure reducer until accumulator pressure drops to 6 bar when process steam consumption reaches the peak period. Boiler load remains stable in every cycle because steam consumption is balanced by the steam accumulator.

The above explanation clearly shows that the steam plant for EPS production should be designed by calculating the steam accumulator volume and boiler operation pressure in proportion before making an investment.

Suit for EPS machine

Photo

修改图片名称
修改图片名称

Leave a Message