Safety Notice of 1500 typ batch pre-expander

Safety Notice of 1500 type batch pre-expander

This page describes the Safety Notice of 1500 typ batch pre-expander.

Suit for EPS machine

Description

  1. If power fails, the steam valve will automatically close, and the compressed air valve open for cooling, avoiding lumps in the chamber. Open the discharge gate manually, and drive the material out with a blower or compressed air.
  2. When using the pre-expander, make sure that the compressed air working pressure is more than 0.5Mpa (5kg). All valves are controlled by compressed air, especially the discharge gate. The discharge gate is locked by an air cylinder, an air pressure decrease will cause the gate to open. To run the machine normally, compressed air pressure should be ensured.
  3. Before reparation, the main power must be cut off. After repairing, remember to take all tools and accessories out of the machine, since they tend to break the steam plate and plow plate in the chamber.
  4. When producing, prevent objects (small stones or iron chips) from entering the chamber with material, since they are easy to break a steam plate.
  5. In producing, often check the sensitivity of the pressure gauge switch, repair or change in time when finding problems.
  6. Machine warning light on in following cases: A. motor overload, thermal relay released B. no material for filling in loader C. discharge gate switch not in right position D. compressed air pressure lower than the set value of pressure gauge switch. E. Expansion chamber pressure higher than the set value of the pressure gauge switch.

Leave a Message