Straight EPS ICF block model with integral foam ties between two panels

ICF Mold for Straight Blocks with EPS Foam Ties

An ICF mold for producing straight EPS blocks whose two side panels are connected by integral EPS foam ties. Start with your block drawing: panel thickness, space between the panels, tie layout and interlocking edges determine the tooling discussion. The illustrated reference design has 55 mm EPS panels and a 140 mm clear space between the panels.

ICF Mold for Integral Foam-Tie Blocks

Straight ICF blocks with integral EPS connections

This mold project is intended for EPS shape-molding producers manufacturing straight insulated concrete form blocks. In the supplied finished-part models, EPS bridges connect the two parallel panels. This distinguishes the design from an ICF system that uses separate plastic connecting inserts.

The model shows the panel faces, repeated foam connections and interlocking edge profiles that need to be considered together when developing the mold. These images explain the block geometry; they are CAD views of the finished EPS part, not photographs of a completed mold.

Define the block before specifying the mold

Two blocks described as “ICF” can require different tooling. The tie profile and spacing, panel thickness, cavity clearance and mating edge geometry should be checked against the buyer’s drawing. The reference dimensions shown here describe the supplied block design and are not dimensions of the mold itself.

The source set includes four straight-part CAD files, identified as Z1200, Z900, Z600 and Z300. These are file identifiers rather than a confirmed dimensional product series. Specify the required finished-block dimensions and drawing revision when requesting a quotation.

Information to send with your inquiry

  • A dimensioned block drawing or STEP model, including overall dimensions and the intended working module.
  • Panel thickness, required clear cavity, foam-tie geometry and tie positions.
  • Interlocking edge details and the adjoining block designs that must fit.
  • Existing EPS shape-molding machine model, platen or mounting drawing and available installation space.
  • Required output, intended EPS material specification and any acceptance requirements for the molded block.

EPSTEC can use these inputs to discuss the project scope. Mold construction, cavity count, equipment interfaces and commercial terms should be confirmed in the project specification before an order is placed.

Features for Block-Design Review

  • Integral EPS foam ties: the supplied design connects the two EPS panels with foam bridges rather than separate plastic inserts.
  • Straight-block geometry: the page focuses on the straight part; corner and junction models in the source folder are retained separately for internal review.
  • Visible mating details: the CAD views show the edge interlocks, panel faces and connection layout for discussion against your drawing.
  • Reference dimensions with a defined scope: 55 mm panel thickness and 140 mm clear spacing refer to the illustrated finished-part design, not mold size or a universal specification.
  • Drawing-led tooling discussion: block dimensions and machine mounting information establish the basis for evaluating the required mold.

Reference Block Parameters

The dimensions below describe the supplied finished-part reference design, not the mold itself. Final dimensions and tolerances follow the approved project drawing.

Item Verified reference Scope
Intended molded part Straight ICF block EPS finished-part design
Connection between panels Integral EPS foam ties Confirmed product identity and supplied CAD
EPS panel thickness 55 mm Illustrated reference design
Clear spacing between inner panel faces 140 mm Illustrated reference design; not mold dimensions
Overall width across the two panels 250 mm 55 + 140 + 55 mm in the checked reference model
Finished-block length, height and tolerances To be confirmed from the approved drawing CAD file names are not a dimensional specification
Mold dimensions, construction and cavity count Project-specific; not yet confirmed No verified mold drawing or mold photograph supplied
Machine mounting and service connections To be checked against the buyer’s machine No universal machine compatibility claim

Annotated Finished-Part References

These original CAD images show the reference panel thickness and inner spacing. They depict the EPS block design, not a completed mold; model colours do not specify mold material or the final EPS colour.

Annotated EPS ICF block design showing 55 mm panel thickness and 140 mm inner spacing
Annotated EPS ICF block design showing 55 mm panel thickness and 140 mm inner spacing

Straight-Block CAD Views

The following six views for each supplied straight-part model show the panel faces, foam connections and interlocking edges. Front, back, left, right, top and bottom follow the source model coordinates. File identifiers do not establish nominal working dimensions.

Z1200 Finished-Part Model

CAD views of the straight EPS ICF block design. Confirm the dimensions and revision required for your project.

Z1200 straight EPS ICF finished-part model, front view
Z1200 straight EPS ICF finished-part model, back view
Z1200 straight EPS ICF finished-part model, left view
Z1200 straight EPS ICF finished-part model, right view
Z1200 straight EPS ICF finished-part model, top view
Z1200 straight EPS ICF finished-part model, bottom view

Z900 Finished-Part Model

CAD views of the straight EPS ICF block design. Confirm the dimensions and revision required for your project.

Z900 straight EPS ICF finished-part model, front view
Z900 straight EPS ICF finished-part model, back view
Z900 straight EPS ICF finished-part model, left view
Z900 straight EPS ICF finished-part model, right view
Z900 straight EPS ICF finished-part model, top view
Z900 straight EPS ICF finished-part model, bottom view

Z600 Finished-Part Model

CAD views of the straight EPS ICF block design. Confirm the dimensions and revision required for your project.

Z600 straight EPS ICF finished-part model, front view
Z600 straight EPS ICF finished-part model, back view
Z600 straight EPS ICF finished-part model, left view
Z600 straight EPS ICF finished-part model, right view
Z600 straight EPS ICF finished-part model, top view
Z600 straight EPS ICF finished-part model, bottom view

Z300 Finished-Part Model

CAD views of the straight EPS ICF block design. Confirm the dimensions and revision required for your project.

Z300 straight EPS ICF finished-part model, front view
Z300 straight EPS ICF finished-part model, back view
Z300 straight EPS ICF finished-part model, left view
Z300 straight EPS ICF finished-part model, right view
Z300 straight EPS ICF finished-part model, top view
Z300 straight EPS ICF finished-part model, bottom view

Applications

For EPS shape-molding manufacturers producing straight ICF blocks with integral foam connections between the panels. The page addresses mold procurement and block-design review. Structural suitability, concrete placement requirements and building approvals must be established for the buyer’s finished ICF system; the CAD images do not establish those performance claims.

Questions Before Specifying Your Mold

How does this design differ from an ICF block with plastic ties?

The supplied design uses EPS foam connections between the two panels. A plastic-tie block uses separate plastic connecting components. Identify the intended connection system before comparing mold quotations; the tooling requirements should follow the actual block drawing.

Do 55 mm and 140 mm describe the mold?

No. They describe the illustrated finished EPS part: 55 mm panel thickness and 140 mm clear spacing between the inner faces. Mold dimensions and the final block specification require separate confirmation.

Are the pictures photographs of the mold?

No. They are views of the supplied finished-part CAD models and original annotated design images. They are used to review geometry and do not establish mold material, machining method or production performance.

What is needed to check the mold against our machine?

Send the machine model and mounting or platen drawing together with the block model, required output and material specification. Compatibility should be checked for the specific machine and mold project.

Are corner and T-junction molds included?

This product page covers the straight-block mold project. Related geometries found in the source directory are kept as internal references; any additional mold requires a separately confirmed scope.

Request a mold discussion

Send your straight ICF block drawing and machine mounting information to EPSTEC. Include panel thickness, cavity spacing and the foam-tie layout so the inquiry starts with the correct product geometry.

Discuss Your Straight ICF Block Mold

Send EPSTEC your block drawing, panel thickness, cavity spacing, foam-tie layout and machine mounting information.

Leave a Message

Loading inquiry form… You can also email [email protected].