EPS Mold for Ceiling Cassette AC Insulation Covers
EPS tooling for producing the insulation cover shared by the two specified 8 HP and 10 HP ceiling cassette AC liner bases. Compare the mold photographs, molded cover samples and drawing references to review the cover-to-base fit and machine interface.
Description
One cover for the two specified liner bases
This page presents the EPS mold used to produce the shared insulation cover for the specified ceiling cassette air conditioner liner designs. The reference cover has a large central circular opening, shaped perimeter sections, raised channels and locating features visible in the sample photographs.
The shared design applies to the specified 8 HP low-base and 10 HP high-base liner pair. It does not establish compatibility with every 8 HP or 10 HP ceiling cassette air conditioner. Confirm the cover drawing and the mating surfaces of both bases together before approving tooling.
Keep the mold, cover and AC unit distinct
The green-and-metal workshop photographs show the tool. The white foam photographs show the molded cover that it produces. The STEP views show a cover component and its inserts; they are not a 3D assembly of the complete mold. The installed ceiling cassette photograph provides application context and does not establish any brand authorization or additional model compatibility.
For a purchasing decision, review the central opening, perimeter fit, locating points, insert requirements and assembly clearances. Then check the mold’s plate, mounting, ejection and connection arrangement against the EPS molding machine. This keeps the component interface and the machine interface in the same tooling discussion.
Features
- Shared cover design: one specified cover is used with the two confirmed liner bases, giving the project a common cover interface to review across those two assemblies.
- Defined cover geometry: sample photographs and the component model show the large circular opening, shaped edges and locating details.
- One-cavity reference: the supplied structural drawing specifies one cavity. Its female side, male side, section and back-plate layout are shown separately below.
- Construction visibility: open mold, rear-side mechanism and back-plate photographs support a discussion of the reference tooling arrangement.
- Trial reference: a photograph shows the EPS cover seated in the mold, and the verified EPSTEC video documents a mold trial. Neither establishes an unmeasured cycle time or production guarantee.
Reference Design Information
| Item | Reference design information |
| Molded material | EPS |
| Molded component | Ceiling cassette AC insulation cover |
| Shared application | The specified 8 HP low-base and 10 HP high-base liner designs only |
| Cavity count | 1, supplied structural drawing |
| Cover overall dimensions | 838 × 825 × 80.8 mm, supplied drawing |
| Template dimensions | 1399 × 1199 × 14 mm, supplied drawing |
| Cover plate dimensions | 1500 × 1300 × 25 mm, supplied drawing |
| Mold wall / reinforcement rib | 12 mm / 12 mm, supplied drawing specification |
| Machine and insert interfaces | Confirm the complete interfaces against the approved design |
Reference design dimensions only. Cover dimensions refer to the molded component; template and cover-plate dimensions refer to tooling parts. Confirm the approved revision and the final specification for your order.
Workshop Photographs
Photographs of the pictured tooling.
Molded Cover Samples
Molded cover reference photographs; check the approved cover-to-base design.
Structural Drawing References
Structural drawing of the cover mold: overview, female mold, male mold, section and back-plate layout. Labels are translated on a display copy; source geometry and dimensions are unchanged.
3D Design References
Six orthographic views of the supplied insulation cover component and inserts. This is the component design reference, not a model of the complete mold. Check its revision against the final cover and mating-base drawings.
Mold Reference Video
Application and Purchasing Information
Ceiling cassette AC insulation liner assemblies
Use this reference when discussing the cover for the specified pair of EPS liner bases. The cover is an internal insulation component; it is not the decorative ceiling panel, an external dust cover or a condensate drain pan.
Related liner mold references:
- EPS insulation liner mold for the specified 8 HP ceiling cassette air conditioner.
- EPS insulation liner mold for the specified 10 HP ceiling cassette air conditioner.
What to send with an inquiry
- Cover and both mating-base drawings or 3D models, with revision identifiers.
- Central opening, locating points, insert details, assembly clearances and tolerances.
- EPS material and density requirements, inspection criteria and target output.
- Shape molding machine details, including mounting, opening stroke, ejection and service connections.
- Any sample-review or trial requirements to include in the order discussion.
Common purchasing questions
Does shared mean universal fit?
No. The shared cover is confirmed for the two specified liner bases only. Review each assembly drawing before applying it to another design.
Are the white cover samples the item being sold?
This page is for the mold that produces them. Specify any sample or molded-part supply requirement separately.
Why are the component model and mold drawing different?
The STEP model describes the cover and inserts. The structural drawing describes the tooling that forms the cover. Each answers a different part of the design review.
Can machine suitability be confirmed from a plate size?
No. Mounting, stroke, ejection, connections and any insert-handling arrangement also need to be checked.
Send the cover and mating-base drawings to [email protected] or use the website inquiry form.






































