Precautions of Pre-foaming machine electrical part

Precautions for Pre-foaming machine electrical part

This page describes precautions for the Pre-foaming machine electrical part.

Suit for EPS machine

Description

1. You must familiarize yourself with the manual and understand its contents before operating the equipment; otherwise, there is a potential danger of accidents to the equipment and to your body;

2. When connecting power cords and motor cords, users must be careful to ensure that the wires are tightly fastened to the terminals; the zero wire (N) and the protective earth wire (PE) should never be mixed together (if at all);

3. Equipment must be reliably grounded before energizing;

4. The thermal relay is already set at the time of operation and does not need to be adjusted, otherwise, it will not protect the motor and will burn it;

5. When switching component specifications, it should meet the design requirements otherwise it is easy to damage the equipment or cause accidents.

6. The power supply should be free of electrical noise caused by welding machine discharge machines or other similar equipment. The grid power should be stabilized at 380+10% (AC, the voltage of the outlet model should be based on the grid voltage of the country and a control transformer should be installed), and it is recommended to add a three-phase AC voltage regulator if the grid power fluctuates too much.

7. The grounding of the machine should be a special grounding grid in the workshop, not the “zero line” of the power grid, the grounding wire should be as short as possible, and the cross-sectional area of the wire should be greater than 6mm2, and the grounding resistance of the grounding grid in the workshop should be less than 4Ω.

8. The installation site should ensure that the door of the electrical cabinet can be opened and closed, not disturbed by other objects, leaving enough space for maintenance and maintenance.

9. Precautions for the first power-on check:

  • First, check the phase sequence of the power supply to ensure that the phase sequence of the incoming power supply is correct.
  • Do not run the machine immediately after the power is turned on, first, add oil to each bearing/guide column of the machine.
  • Check whether the gas circuit and oil circuit are installed correctly, whether the readings of each meter are normal, whether the installation of the valve is correct, and whether the operation is normal.
  • All of the above are normal, the machine can run.

10. Precautions for daily power on for normal work:

  • Before plugging in the power and preparing to run the machine, make sure that there is no one around the moving parts of the machine and that no other objects are obstructing the movement of the machine.
  • After the power is turned on, check the pressure gauges, moving parts, and other electrical parts to ensure that they can work normally.
  • If the machine is shut down due to grid power failure, the main power switch on the electrical cabinet should be immediately turned to the “0” position.

11. Precautions when the machine is running:

  • Only one person is allowed to operate the machine at any time, and the operator should be familiar with the operating steps of the machine, two or more operators are never allowed to operate the machine at the same time if it is really necessary for two people to operate the machine at the same time, then the two operators should coordinate their work with each other.
  • Turn off the power of the machine before performing the installation of the machine or the person doing other work on the side of the workbench.
  • When the mixing motor is running, it is never allowed to open the observation window on the drum and the discharge door parts for other work such as maintenance.
  • Pay special attention not to loosen the hair of the clothing to prevent it from being entangled in the moving parts of the machine, and wear work clothes and safety shoes and hats when working.
  • Before operating the button or switch on the panel, look at it before operating, do not press the button and turn the switch at will.
  • Do not touch the switch or button with wet hands, otherwise it may cause a short circuit or another electrical failure.

12. Precautions when repairing the machine:

  • Before overhauling or cleaning the inside of electrical equipment, turn off all power switches and hang up the maintenance tag, otherwise, someone mistakenly operates the machine, and the power is not turned off, which will cause serious personal injury.
  • In the case of live electricity, it is never allowed to carry out any form of repair of the electrical control part, the drive part, otherwise it will cause personal injury or death and damage to the electrical control system of the machine.
  • It is strictly forbidden to operate the main circuit switch 1 on the drive unit when the machine is powered on.
  • It is strictly forbidden to unplug or insert the storage module of the PLC or touch screen when the machine is powered on.
  • Unless required for maintenance, the electrical control cabinet and solenoid valve box of the machine should be closed and fixed, otherwise, dust will enter, causing electrical failure.
  • The solenoid valve is allowed to rise in temperature when working, so do not touch it immediately after power failure and let it cool down for a while.
  • The weighing system, especially the tension sensor part, is strictly forbidden to impact artificially, otherwise, it will lead to inaccurate weighing.
  • Each potentiometer on the circuit board has been adjusted before leaving the factory and should not be changed casually.
  • The various parameters of the weighing indicator have been adjusted before leaving the factory, and it is strictly forbidden to change them at will, otherwise, the weighing system will not work normally.
  • The machine, especially the barrel, is not allowed to leave any debris after maintenance, otherwise, it will cause new damage to the machine.

13. Precautions after the machine is powered off:

  • After the machine is powered off, the machine, especially the foaming barrel, should be cleaned up, and there should be no foam particles remaining to prevent material accumulation in the barrel.
  • Turn off the machine’s compressed air, steam, and the machine’s total power supply. Pay special attention when turning off the touch screen, First exit the PC system, then turn off the Windows system, and finally turn off the total power of the machine.
  • Do a good job of environmental clean-up on-site.

Leave a Message