修改图片名称

How to set the dry room temperature

This page provides instructions on how to set the temperature in a dry room, specifically for an Oven machine. The page includes information on troubleshooting and problem-solving, as well as photos and videos to aid in identifying and solving issues. The machine type, model, country, and status of the machine are also listed. The page is written by Sam Xie and includes media in the form of images. The text provides both Chinese and English descriptions of the problems encountered and the steps taken to resolve them. The solution involves setting the temperature sensor temperature difference and temperature setting in the drying room, which can be adjusted based on demand.

Problem description

Needs bit more explanation. We guessing and probably ok. But wants to know the proper work ethic.

修改图片名称

Solution

The dry room temerature can be set based on demand.

Temperature sensor temperature difference setting: when the temperature difference between the upper and lower layers in the drying room exceeds No. 2, the fan of the thermal circulation is turned on, when the temperature difference between the upper and lower layers is lower than No. 1, the fan of the thermal circulation is turned off, this setting is mainly to start and stop the circulation of the thermal fan, its role is to balance the upper and lower temperatures in the drying room.

Temperature setting in the drying room: when the lower temperature in the drying room is lower than No. 3, the inlet and outlet angle valves are opened and the pipeline circulates hot water. Above setting 4 the inlet and outlet angle valves are closed and the branch angle valves are opened. Hot water is not circulated through the pipes and heating of the drying room is stopped.

1=5 2=40
3=50 4=60