How to reset the motor after thermal overload of EPS hot melting machine

How to reset the motor after thermal overload of EPS hot melting machine

In case of thermal overload in an EPS hot melting machine, the machine triggers thermal protection. To reset, open the electrical control cabinet and manually reset the protector to the “ON” position. The reset method may vary depending on the machine type and country, but all require manual intervention.

Description

When the EPS hot melting machine is working, if it encounters EPS waste with too high density, it will experience thermal overload. At this time, the machine will automatically trigger thermal protection.

When thermal protection is in effect, you cannot resume production of the EPS hot melting machine only through the button outside the electrical control cabinet.

We need to open the electrical control cabinet, and turn the protector inside the electrical control cabinet clockwise to the “ON” position.

Due to different countries and different types of electrical appliance configurations for different type of EPS hot melting machine, some protector inside the electric control cabinet need to be pushed up, some need to be rotated to reset, but in the end, they are all the same, requiring manual reset.

How to reset the motor after thermal overload of EPS hot melting machine

Leave a Message