How to reset he initial position after installing a new mould for EPS shape molding machine

How to reset the initial position after installing a new mould for EPS shape molding machine

This page provides instructions on how to reset the initial position after installing a new mold for an EPS shape molding machine.

Suit for EPS machine

Description

When changing the EPS mold, we should do the following settings on the touch screen to reset the initial position.

  1. After changing the EPS mold, click the Close mould button and the Lock button, then observe whether the hydraulic display reaches between 110~120 bar.
  2. When the pressure reaches the reasonable range and remains, click the Reset button, this completes the zero position setting of the new EPS mold.