Suit for EPS machine
Description
When changing the EPS mold, we should do the following settings on the touch screen to reset the initial position.
- After changing the EPS mold, click the Close mould button and the Lock button, then observe whether the hydraulic display reaches between 110~120 bar.
- When the pressure reaches the reasonable range and remains, click the Reset button, this completes the zero position setting of the new EPS mold.

Video