Suit for EPS machine
Troubleshooting analyse
Pls reply below questions to find out why the servo drive is burned out. Normally this servo drive will not be easy to damage.
- Is the EPS cutting line disassembled and reinstalled?
- Is the servo drive burned due to incorrect wiring, connecting 220V instead of 415V?
- Before we send out the servo motor, We need to set the parameters in advance. Please take a photo to confirm if it is the left servo motor or the right servo motor. Please take the photo corresponding to the EPS cutting line position.
Damage photo




Solution
- P2-08 10 Parameter Reset
- P2-15 00
- P2-16 00
- P2-17 00
- P1-01 000 Direction (set to 100 if opposite to the direction in maintenance mode)
- P1-72 10000
- P1-73 1000
- P2-10 0001 Enable Start 0101 Enable Stop
After completing the above parameter settings, manually travel a certain distance in the upward direction.
Next, check parameters P5-16 and P5-17.
If both P5-16 and P5-17 have two decimal points or neither of them have two decimal points (set P1-74 to 0002)
If one of the parameters, either P5-16 or P5-17 has a decimal point while the other does not (set P1-74 to 0102)
Note: Make sure to disable (P2-10 Enable) when setting all parameters. Re-enable after completing the settings.
Different types of servo motor drive

Old-type servo motor driver
- DELTA
- MODEL: ASD-A2-1521-L
- Power: 1.5KW
The order in which the parameters are set in sequence
- P2-10 to 101
- P2-08 to 10
- P2-15 to 0
- P2-16 to 0
- P2-17 to 0
- P1-44 to 128
- P1-45 to 10
- P2-10 to 1

New type servo motor driver
- DELTA
- MODEL: ASD-A2-1521-M
- Power: 1.5KW
The order in which the parameters are set in sequence
- P2-10 to 101
- P2-08 to 10
- P2-15 to 0
- P2-16 to 0
- P2-17 to 0
- P1-44 to 128
- P1-45 to 1
- P2-10 to 1
Leave a Message