EPS cutting line horizontal cut wire broken wire alarm

The post includes information on the machine type, model, and country, as well as problem photos and videos, problem descriptions in Chinese and English, troubleshooting analysis in Chinese and English, and solutions in Chinese and English.

The post provides a step-by-step guide to troubleshooting the problem, including instructions on how to adjust the constant current value.

Description

First, when the wire break alarm occurs, the EPS cutting line will stop and the cutting wire will stop heating.

In order to narrow down the scope of troubleshooting, please turn off the wire break alarm for the 2nd phase cutting and the 3rd phase cutting, only turn on the wire break alarm for the 1st phase cut only.

If there is a broken wire alarm and the cutting line stops, but the cutting wire continues to heat up, it means there is a problem with the program. What we have to solve is the problem of the program. Not the problem of cutting line setting.

Please clarify this problem for customers first.

Working Principle

There is a relationship between the cutting temperature and the correction value.

When cutting high-density EPS block, because of the increase in density, it is necessary to adjust the cutting temperature accordingly, and when the temperature increases, the corresponding correction value should also be increased accordingly.

The constant current value can be set by the gear icon in the lower right corner of the power regulator panel

Check the setting value of the constant current value of the power regulator and the actual current output value of the power regulator when cutting, and make the actual constant current value as close as possible to the set constant current value. In the case of cutting the number of electric heating wire is unchanged, only need to adjust the cutting speed, you can actually cut different density of the EPS block, no need to frequently adjust the power regulator

Hands-on.

The actual constant current value setting, the first need to set the constant current value to 100A, by manually heating the electric heating wire, observe the actual output current value, and then adjust the constant current value, as long as the number of electric heating wire and input voltage any one of the two changes in the need to repeat the above operation