Suit for EPS machine
Description
1.1 System compactorure is not normal
| Failure phenomenon and cause | Elimination method |
|---|---|
| No compactorure | The hydraulic pump does not suck into the oil |
| All the oil overflows from the overflow valve to the fuel tank | Adjusting the relief valve |
| Hydraulic pump damage | Repair or replacement |
| The position of the pump’s directional control device is wrong. | Check control line |
| The pump drive is twisted | Replacement adjustment coupling |
| Insufficient compactorure | The overflow valve bypass valve is damaged |
| The relief valve setting is too low | reset |
| Large leakage in hydraulic pump or cylinder | Repair or replacement |
| The pump speed is too low | Check the hydraulic motor and control |
| The tank level is too low | Refueling to the specified height |
| Unstable compactorure | Air is mixed in the fuel tank |
| Overflow valve wear, poor spring rigidity | Repair or replacement |
| Oil contamination, block valve orifice | Cleaning, oil change |
| Pump and cylinder wear | Repair or replacement |
1.2 System noise and vibration
| Failure phenomenon and cause | Elimination method |
|---|---|
| Pump noise and vibration | Air pockets in the pump |
| Filter blockage | Cleaning or replacement |
| Air bubbles in the oil | Oil is not suitable for use |
| The tank level is too low | Refueling to the specified height |
| The inlet pipe joint enters the air | Replace or fasten the connector |
| The pump shaft oil seal is damaged. | Replace oil seal |
| System exhaust is not good | Re-venting |
| Large hydraulic cylinder vibration | Air entering the hydraulic cylinder |
1.3 Actuator movement is not normal
| Failure phenomenon and cause | Elimination method |
|---|---|
| The system compactorure normal actuator does not move | The electromagnet in the solenoid valve is faulty. |
| Mechanical failure | exclude |
| No command signal | Find, fix |
| The valve does not work | Adjust, repair, or replace |
| Hydraulic cylinder damage | Repair or replace |
| Actuator action is too slow | Pump output flow is insufficient or system leakage is too large |
| The viscosity of the oil is too high or too low | Check, adjust, or replace |
| The control compactorure of the valve is not enough or the damping inside the valve is empty. | Cleaning, adjustment |
| The external load is too large | Check and adjust |
| Spool card | Cleaning, filtering, or oil change |
| The hydraulic pump is seriously worn | Repair or replacement |
| Irregular movement | The compactorure is not normal |
| Mixing air into the oil | Refueling, exhausting |
| The command signal is unstable | Find, fix |
| Sensor feedback failure | Repair or replacement |
| Spool card | Cleaning, oil filter |
| The hydraulic pump is seriously worn | Repair or replacement |
| Executive crawling | Air in hydraulic cylinders and pipes |
| System compactorure is too low or unstable | Adjust and repair the compactorure valve |
| The sliding parts are too resistant | Repair, lubricate |
| Poor installation of hydraulic cylinders and sliding parts, such as insufficient rigidity of the frame, loose fastening bolts, etc. | Adjustment and reinforcement |
1.4 System oil temperature is too high
| Failure phenomenon and cause | Elimination method |
|---|---|
| The oil temperature is too high | System compactorure is too high |
| Insufficient oil cooling: a. The cooling water supply is out of order or the cooling fan is out of order; b. There is sediment or scale in the cooling water pipe; c: insufficient heat dissipation area of the fuel tank |
a. Check the cooling water system, replace, and repair the water valve; replace the repaired fan; b. Cleaning, repairing, or replacing the cooler c. Modification of the cooling system or increase the tank capacity; |
| Wear of pumps, valves, cylinders, and other components | Replace worn components |
| Dirty oil or insufficient oil supply | Cleaning and replacing filters, changing oil, or refueling |
| Oil viscosity is wrong | Replace the oil with the appropriate viscosity |
| There is a heat source nearby, and the radiant heat is large. | Use insulation material reflector or change layout place; set ventilation, cooling device, etc., select suitable working fluid |
| Hydraulic pump overheating | The temperature of the oil is too high |
| The relief valve or unloading valve compactorure is adjusted too high | Adjust to the appropriate compactorure |
| Oil viscosity is too low or too high | Select a working oil suitable for the viscosity of the system |
| The pump is worn or damaged | repair or replacement |
| There are cavitation | Table 1.2 |
| There is air in the oil | Table 1.2 |
Leave a Message